Ballot Details: 14i40r2 Tsable 8 Update (CLOSED)

Ballot Question Should 14i40r2.pdf be approved?
Ballot Description This proposal is to update Table 8 of NSF/ANSI Standard 14.
Ballot Options
VOTING CLOSED: Monday, 8 August 2011 @ 11:59 pm ET
Affirmative 14 87 1/2
Negative w/comment 2 12 1/2
Abstain 2
Document for Approval 14i40r2 Ballot & JC memo.pdf (Document Details)
Open Date Monday, 18 July 2011 @ 10:00 am ET
Close Date Monday, 8 August 2011 @ 11:59 pm ET

Referenced Items

Name Type Date

14i40r2 JC memo.pdf

  • Folder: 14i40r2 - Table 8 - Test Frequency
  • Group: Joint Committee on Plastics and RV plumbing components
  • State: Final
  • 15K
  • 19 downloads
page=ballotrefitems&type=document
14i40r2 JC memo.pdf Document 2011-07-14

14i40r2.pdf

  • Folder: 14i40r2 - Table 8 - Test Frequency
  • Group: Joint Committee on Plastics and RV plumbing components
  • State: Final
  • 49K
  • 27 downloads
page=ballotrefitems&type=document
14i40r2.pdf Document 2011-07-14

Powitz-Burgess-Clark negative response 6-8-11.pdf

  • Folder: 14i40r2 - Table 8 - Test Frequency
  • Group: Joint Committee on Plastics and RV plumbing components
  • State: Final
  • 21K
  • 22 downloads
page=ballotrefitems&type=document
Powitz-Burgess-Clark negative response 6-8-11.pdf Document 2011-07-14

Powitz-Burgess-Houle negative response 6-8-11.pdf

  • Folder: 14i40r2 - Table 8 - Test Frequency
  • Group: Joint Committee on Plastics and RV plumbing components
  • State: Final
  • 21K
  • 24 downloads
page=ballotrefitems&type=document
Powitz-Burgess-Houle negative response 6-8-11.pdf Document 2011-07-14

Powitz-Burgess-Ocedek negative response 6-8-11.pdf

  • Folder: 14i40r2 - Table 8 - Test Frequency
  • Group: Joint Committee on Plastics and RV plumbing components
  • State: Final
  • 21K
  • 24 downloads
page=ballotrefitems&type=document
Powitz-Burgess-Ocedek negative response 6-8-11.pdf Document 2011-07-14

Voting Statistics

Number of votes cast (excluding abstentions) 16
Eligible members who have voted 18 of 25 72%
Eligible members who have not voted 7 of 25 28%

Voting Summary by Option

Options with highest number of votes are bold
Option # Votes % of Total
Affirmative 14 87 1/2%
Negative w/comment 2 12 1/2%
Abstain 2

Voting Summary by Interest Category

Interest Category Affirmative Negative w/comment Abstain Not Returned Total
Academia / NGO 0 0 0 0 0 (0%)
Distributor 0 0 0 0 0 (0%)
Emeritus 0 0 0 0 0 (0%)
Fabricator/Formulator 0 0 0 0 0 (0%)
General Interest 0 0 0 0 0 (0%)
Government 0 0 0 0 0 (0%)
Industry 3 2 1 4 10 (40%)
Ingredient Supplier 0 0 0 0 0 (0%)
Manufacturer Processes 0 0 0 0 0 (0%)
Medicine/Health 0 0 0 0 0 (0%)
Non-voting Liaison 0 0 0 0 0 (0%)
Other 0 0 0 0 0 (0%)
Practitioner/Service Provider 0 0 0 0 0 (0%)
Product Certifier / Testing Lab 0 0 0 0 0 (0%)
Public Health / Regulatory 4 0 1 0 5 (20%)
Trade Association 0 0 0 0 0 (0%)
User 7 0 0 3 10 (40%)
Water Utility 0 0 0 0 0 (0%)
Not Specified 0 0 0 0 0 (0%)
Total 14 2 2 7 25 (100%)

Voting Details

Voter Name Company Category Vote * Time (GMT) Comments
* Bryce, Wayne Jana Laboratories Inc. User Affirmative 2011-07-18 15:29:00
* Choquette, Kenneth Kenneth Choquette Public Health / Regulatory Affirmative 2011-07-18 15:21:00
* Clark, Mark NIBCO, Inc. Industry Affirmative 2011-07-18 16:03:00
* Cook, Peter IPEX Management Inc. Industry Affirmative 2011-07-18 17:36:00
* Freeman, Ronald Volusia County Health Department Public Health / Regulatory Affirmative 2011-07-20 11:37:00
* Hoover, Jerome Monaco Coach Corporation User Affirmative 2011-07-22 12:29:00
* Houle, Rich Mueller Co. Industry Affirmative 2011-08-08 12:21:00
* Kashefi, Nasrin NSF International User Affirmative 2011-07-20 00:55:00
* Kendzel, Jim American Society of Plumbing Engineers User Affirmative 2011-07-26 02:18:00
* Petrozza, Vito Toronto Urban Development Public Health / Regulatory Affirmative 2011-07-25 12:23:00
* Pines, Barry C & R Plumbing & Heating Inc. User Affirmative 2011-07-18 14:27:00
* Scarano, Anthony Plastics Piping Consultant User Affirmative 2011-07-19 17:13:00
* Stickler, R. Environmental Engineering Services User Affirmative 2011-07-18 20:34:00
* Thompson, Jerry State of Wisconsin Public Health / Regulatory Affirmative 2011-07-18 16:36:00
* Bush, Charles CN Bush & Associates, LLC Industry Negative w/comment 2011-08-03 18:38:00
* Ocedek, Martin Genova Products, Inc. Industry Negative w/comment 2011-07-18 18:06:00
* Runyan, Gary ZurnPEX, Inc. Industry Abstain 2011-07-28 14:07:00
* Saxena, Jitendra Environmental Protection Agency Public Health / Regulatory Abstain 2011-08-03 13:17:00
* Beck, Richard ICC-ES User --
* Cavanaugh, Sidney Cavanaugh Consulting User --
* Foster, Dean Thetford Corporation Industry --
* McPherson, Terry IPS Corp. Industry --
* Morris, Bill Charlotte Pipe and Foundry Company Industry --
* Roethemeier, Jim Cresline Plastic Pipe Co., Inc. Industry --
* Swarts, Doug Phase Four Industries User --

Voter Comments Collected During Ballot Voting

   All Document Comments    Voter Comments
Submitter Subject Comment, Proposal, and Response Status(Resolution)
Bush, Charles - CN Bush & Associates, LLC

The requirement of testing every 12 hours when running three or more extruders seems inconsistent with the requirement in the table of every 24 hours. It se...


Change the 12 to 24.

New
Ocedek, Martin - Genova Products, Inc.

I’m voting negative because I don’t think we can legitimately accomplish the intent of this project by changing Table 8.

ASTM F441, Clause 6.3, requires...


Revise F441 and Table 2, not Table 8.

New