Monica Leslie has updated the comment Flow rate and structural integrity test to the document Combined ADJ 53i79r7.1 et al & JC memo.pdf in the Joint Committee on Drinking Water Treatment Units group. Subject : Flow rate and structural integrity test Category : Substantive Comment As shown in the data provided by BRITA GmbH, I still recommend a flow rate of 600 ml/min. The tolerance may be +/- 10 % or, if this is to thight, +/- 80 ml. I don't see a need for the structural integrity test of squeeze bottles. I recommend to add for performance testing of squeeze bottles something like: If the bottle leaks or fails during the performance test, the test result is a fail. Proposal No proposal provided. Comment Number : #04342 Submitter : Monica Leslie Date submitted : 2013-08-19 08:13:02 Status : New View Comment Details View Document Details Download Document