Description
On behalf of Sal Aridi, Issue proponent, the ballot for NSF/ANSI 50, issue 87, revision 1, repeatability criteria for flow through feeders, has been recommended to be sent to the Joint Committee for consideration.  Please review the proposal and return your ballot by the ballot due date of May 30, 2013 via the online workspace (http://standards.nsf.org).

When adding comments, please identify the section number/name for your comment and add all comments under one comment number where possible.  If you need additional space, please upload a word or pdf version of your comments online via the browse function.

Purpose

The purpose of this ballot is to replace the current repeatability variance for each output measurement to a 10% limit on the average of the 5 repeatability measurements at both 50% and 100% output.
Ballot Options Ballot has closed
[ ] Affirmative
[ ] Negative
[ ] Abstain
Document for Approval 50i87r1 Output Repeatability.pdf