Public Workspaces

Title Approval of 42i110r1 et al - Air Gaps for Drinking Fountains
Description
Proposed revisions to NSF/ANSI 42 – Drinking Water Treatment Units - Aesthetic Effects, NSF/ANSI 53 – Drinking Water Treatment Units - Health Effects, NSF/ANSI 55 – Ultraviolet Microbiological Water Treatment Systems, NSF/ANSI 58 – Reverse Osmosis Drinking Water Treatment Systems, NSF/ANSI 62 – Drinking Water Distillation Systems, NSF/ANSI 244 – Supplemental Microbiological Water Treatment Systems – Filtration, and NSF/ANSI 401 – Drinking Water Treatment Units - Emerging Compounds / Incidental Contaminants.

The proposed revision clarifies the requirements for drinking fountains under the general performance requirements of section 6 of the DWTU standards. The ballot also revises the minimum air gap requirement for drinking fountain outlets from 2 inches to 1 inch to be aligned with other industry standards and codes.
Ballot Options Ballot has closed
[ ] Affirmative
[ ] Negative
[ ] Abstain
Document for Approval 42i110r1 et al - JC Memo & Ballot.pdf
Opening Date Thu, Dec 17 2020 1:00 pm Eastern Standard Time
Closing Date Thu, Jan 7 2021 11:59 pm Eastern Standard Time
Ballot has closed.

Referenced Items

Name Type Date Actions

06770: Approval of 42i110r1 et al - Air Gaps for Drinking Fountains

Document (Archive)

2021-01-08

No Access

2020 DWTU JC Meeting Summary Excerpt - DWTU-2020-12.pdf

Document

2020-12-16

No Access

DWTU-2020-12_Air Gap for Fountains.pdf

Document

2020-12-16

No Access

- Voting Results

Voting Statistics

Number of votes cast (excluding abstentions) 26
Eligible members who have voted 26 of 32 81.25%
Eligible members who have not voted 6 of 32 18.75%

Voting Summary by Option

Options with highest number of votes are bold
Option # Votes % of Total
Affirmative 26 100%
Negative w/comment 0 0%
Abstain 0

Voting Summary by Interest Category

Interest CategoryAffirmativeNegative w/commentAbstainNot ReturnedTotal
Academia / NGO00000 (0%)
Distributor00000 (0%)
Emeritus00000 (0%)
Fabricator/Formulator00000 (0%)
General Interest00000 (0%)
Government00000 (0%)
Industry900211 (34.375%)
Ingredient Supplier00000 (0%)
Manufacturer00000 (0%)
Manufacturer Processes00000 (0%)
Medicine/Health00000 (0%)
Non-voting Liaison00000 (0%)
Other00000 (0%)
Other Industry00000 (0%)
Practitioner/Service Provider00000 (0%)
Product Certifier / Testing Lab00000 (0%)
Public Health / Regulatory800210 (31.25%)
Purchasers & Ecolabel Criteria Users00000 (0%)
Sustainability Advocate & Gov00000 (0%)
Trade Association00000 (0%)
User900211 (34.375%)
Water Utility00000 (0%)
Not Specified00000 (0%)